 INPUT

 Input Voltage Range

 Min - 200 VAC, Nor - 220 VAC, Max - 260 VAC

 Input Frequency Range

 Nor - 60 Hz

 Input Current  220 VAC in, 30 W output 
 Power Factor (Typical)  220 VAC
 Inrus Current  At 230 VAC VAC input, 25 ¡ÆC cold start 

 OUTPUT

 Line Regulation

 Nor - ¡¾2%

 Load Regulation

 Nor - ¡¾2% 

 Voltage Accuracy

 % of Vout ( Nor - ¡¾5 % )

 Ripple and Noise

 20MHz Bandwidth ( Nor - 500 mV )

 Trun-on Delay  Measured at 220 VAC and full lod ( Nor - 1s )
 Short Circuit Protection  Auto Recovery
 Over Voltage Protection  Non-latching. See individual moldels OVP levels

GENERAL

 Isolation Voltage

 Input to Chassis ( Nor - 3000 VAC )

 Efficiency (Typical)  See individual models 
 No load Power Dissipation  Measured at 100 VAC and 220 VAC ( Nor - 1.0 W )
 Lifetime  Load 100% at 30 ¡ÆC ( Nor - 40000 Hour )
 Weight  170 g
 Operating Temperature  Min. -30 ¡ÆC, Max. +50 ¡ÆC
 Storage Temperature  Min. -30 ¡ÆC, Max. +70 ¡ÆC
 Relative Humidity  Min. 10, Max 90 %RH
 Power Derating

 At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

 At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

EMC

 Emissions

 

 Conducted

 EN55015 ( Level B )

 Radiated  EN55015 ( Level B )
 Harmonic Distortion  EN61000-3-2 ( Compliant )
 Flicker and Fluctuation  EN61000-3-2 ( Compliant )
 Immunity  
 ESD  EN61000-4-2 ( Level 4 )
 Radiated RFI  EN61000-4-3 ( Level 3 )
 Fast Transients - burst  EN61000-4-4 ( Level 4 )
 Input Line Surges  EN61000-4-5 ( Level 4 )
 Conducted RFI  EN61000-4-6 ( Compliant )
 Power Freq Magnetic Field  EN61000-4-8 ( Compliant )
 Voltage Dips  EN61000-4-11 ( Compliant )

OTHERS

 Case size

 26x20x178 mm (WxHxD)

 Weight

 170 g


â´Ý±â
NCP30-NF-12 ¡¦ NCP Series [Á¦Á¶»ç:¿£¾¾¿¤À̵ð - »ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC200~260V], [Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/2.5A], 30W, single, Waterproof, Cable, ALV, Cable, È¿À²:83%, 170g

0°³
1~1 : 8,200¿ø
2~9 : 8,100¿ø
10~19 : 8,000¿ø
20~49 : 8,000¿ø
50~99 : 7,700¿ø
100~299 : 7,500¿ø
ÆÇ¸ÅÁß
À̺¥Æ®Áß


9

Á¦Ç°ÀÇ »ç¾ç

 INPUT

 Input Voltage Range

 Min - 200 VAC, Nor - 220 VAC, Max - 260 VAC

 Input Frequency Range

 Nor - 60 Hz

 Input Current  220 VAC in, 60 W output ( Max - 0.72 A )
 Power Factor (Typical)  220 VAC
 Inrus Current  At 230 VAC VAC input, 25 ¡ÆC cold start ( Max - 40 A )

 OUTPUT

 Line Regulation

 Nor - ¡¾2%

 Load Regulation

 Nor - ¡¾2% 

 Voltage Accuracy

 % of Vout ( Nor - ¡¾5 % )

 Ripple and Noise

 20MHz Bandwidth ( Nor - 500 mV )

 Trun-on Delay  Measured at 220 VAC and full lod ( Nor - 1s )
 Short Circuit Protection  Auto Recovery
 Over Voltage Protection  Non-latching. See individual moldels OVP levels

GENERAL

 Isolation Voltage

 Input to Chassis ( Nor - 3000 VAC )

 Efficiency (Typical)  See individual models ( Nor - 83.0% )
 No load Power Dissipation  Measured at 100 VAC and 220 VAC ( Nor - 1.0 W )
 Lifetime  Load 100% at 30 ¡ÆC ( Nor - 40000 Hour )
 Weight  330 g
 Operating Temperature  Min. -30 ¡ÆC, Max. +50 ¡ÆC
 Storage Temperature  Min. -30 ¡ÆC, Max. +70 ¡ÆC
 Relative Humidity  Min. 10, Max 90 %RH
 Power Derating

 At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

 At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

EMC

 Emissions

 

 Conducted

 EN55015 ( Level B )

 Radiated  EN55015 ( Level B )
 Harmonic Distortion  EN61000-3-2 ( Compliant )
 Flicker and Fluctuation  EN61000-3-2 ( Compliant )
 Immunity  
 ESD  EN61000-4-2 ( Level 4 )
 Radiated RFI  EN61000-4-3 ( Level 3 )
 Fast Transients - burst  EN61000-4-4 ( Level 4 )
 Input Line Surges  EN61000-4-5 ( Level 4 )
 Conducted RFI  EN61000-4-6 ( Compliant )
 Power Freq Magnetic Field  EN61000-4-8 ( Compliant )
 Voltage Dips  EN61000-4-11 ( Compliant )

OTHERS

 Case size

 44.4 X 36.4 X 160.5 mm (WxHxD)

 Weight

 330 g


â´Ý±â
NCP60-NF-12 ¡¦ NCP Series [Á¦Á¶»ç:¿£¾¾¿¤À̵ð - »ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC200~260V], [Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/5A], 60W, single, Waterproof, Cable, ALV, Cable, È¿À²:85%, 330g

0°³

1~1 : 13,200¿ø
2~9 : 13,100¿ø
10~19 : 12,900¿ø
20~49 : 12,800¿ø
50~99 : 12,400¿ø
100~299 : 12,100¿ø
̵̧
Á¦Ç°

À̺¥Æ®Áß


8

Á¦Ç°ÀÇ »ç¾ç

 INPUT

 Input Voltage Range

 Universal Input ( Min - 100 VAC, Nor - 220 VAC, Max - 240 VAC )

 Input Frequency Range

 Min - 50 Hz, Max - 60 Hz

 Input Current  100 VAC in, 60 W output ( Max - 0.8 A higher)
 Power Factor (Typical)  220 VAC, 110 VAC ( Min - 0.95, Max - 0.98 )
 Inrus Current  At 230 VAC VAC input, 25 ¡ÆC cold start ( Max - 40 A )

 OUTPUT

 Line Regulation

 Nor - ¡¾2%

 Load Regulation

 Nor - ¡¾2% 

 Voltage Accuracy

 % of Vout ( Nor - ¡¾5 % )

 Ripple and Noise

 20MHz Bandwidth ( Nor - 500 mV )

 Trun-on Delay  Measured at 220 VAC and full lod ( Nor - 1s )
 Short Circuit Protection  Auto Recovery
 Over Voltage Protection  Non-latching. See individual moldels OVP levels

GENERAL

 Isolation Voltage

 Input to Chassis ( Nor - 3000 VAC )

 Efficiency (Typical)  See individual models ( Nor - 83.0% )
 No load Power Dissipation  Measured at 100 VAC and 220 VAC ( Nor - 1.0 W )
 Lifetime  Load 100% at 30 ¡ÆC ( Nor - 40000 Hour )
 Weight  330 g
 Operating Temperature  Min. -30 ¡ÆC, Max. +50 ¡ÆC
 Storage Temperature  Min. -30 ¡ÆC, Max. +70 ¡ÆC
 Relative Humidity  Min. 10, Max 90 %RH
 Power Derating

 At 100VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

 At 240VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

EMC

 Emissions

 

 Conducted

 EN55015 ( Level B )

 Radiated  EN55015 ( Level B )
 Harmonic Distortion  EN61000-3-2 ( Compliant )
 Flicker and Fluctuation  EN61000-3-2 ( Compliant )
 Immunity  
 ESD  EN61000-4-2 ( Level 4 )
 Radiated RFI  EN61000-4-3 ( Level 3 )
 Fast Transients - burst  EN61000-4-4 ( Level 4 )
 Input Line Surges  EN61000-4-5 ( Level 4 )
 Conducted RFI  EN61000-4-6 ( Compliant )
 Power Freq Magnetic Field  EN61000-4-8 ( Compliant )
 Voltage Dips  EN61000-4-11 ( Compliant )

OTHERS

 Case size

 44.4 X 36.4 X 160.5 mm (WxHxD)

 Weight

 330 g


â´Ý±â
NCP60-PF-12 ¡¦ NCP Series [Á¦Á¶»ç:¿£¾¾¿¤À̵ð - »ý»ê±¹:Korea]
[ÀÔ·ÂÀü¾Ð: AC90~240V], [Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/5A], 60W, single, Waterproof, Cable, ALV, Cable-PFC, È¿À²:85%, 330g

19°³

1~1 : 23,000¿ø
2~9 : 22,800¿ø
10~19 : 22,500¿ø
20~49 : 22,300¿ø
50~99 : 21,600¿ø
100~299 : 21,200¿ø
ÆÇ¸ÅÁß


7

Á¦Ç°ÀÇ »ç¾ç

 INPUT

 Input Voltage Range

 Nor - 220 VAC

 Input Frequency Range

 Nor - 60 Hz

 Input Current  100 VAC in, 100 W output ( Max - 1.2 A )
 Power Factor (Typical)  
 Inrus Current  At 230 VAC VAC input, 25 ¡ÆC cold start ( Max - 40 A )

 OUTPUT

 Line Regulation

 Nor - ¡¾2%

 Load Regulation

 Nor - ¡¾2% 

 Voltage Accuracy

 % of Vout ( Nor - ¡¾5 % )

 Ripple and Noise

 20MHz Bandwidth ( Nor - 500 mV )

 Trun-on Delay  Measured at 220 VAC and full lod ( Nor - 1s )
 Short Circuit Protection  Auto Recovery
 Over Voltage Protection  Non-latching. See individual moldels OVP levels

GENERAL

 Isolation Voltage

 Input to Chassis ( Nor - 2000 VAC )

 Efficiency (Typical)  See individual models ( Nor - 83.0% )
 No load Power Dissipation  Measured at 100 VAC and 220 VAC ( Nor - 1.0 W )
 Lifetime  Load 100% at 30 ¡ÆC ( Nor - 40000 Hour )
 Weight  850 g
 Operating Temperature  Min. -20 ¡ÆC, Max. +50 ¡ÆC
 Storage Temperature  Min. -20 ¡ÆC, Max. +70 ¡ÆC
 Relative Humidity  Min. 10, Max 90 %RH
 Power Derating

 At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

 At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

EMC

 Emissions

 

 Conducted

 EN55015 ( Level B )

 Radiated  EN55015 ( Level B )
 Harmonic Distortion  EN61000-3-2 ( Compliant )
 Flicker and Fluctuation  EN61000-3-2 ( Compliant )
 Immunity  
 ESD  EN61000-4-2 ( Level 4 )
 Radiated RFI  EN61000-4-3 ( Level 3 )
 Fast Transients - burst  EN61000-4-4 ( Level 4 )
 Input Line Surges  EN61000-4-5 ( Level 4 )
 Conducted RFI  EN61000-4-6 ( Compliant )
 Power Freq Magnetic Field  EN61000-4-8 ( Compliant )
 Voltage Dips  EN61000-4-11 ( Compliant )

OTHERS

 Case size

 78 X 44 X 165 mm (WxHxD)

 Weight

 850 g


â´Ý±â
NCP100-NF-12 ¡¦ NCP Series [Á¦Á¶»ç:¿£¾¾¿¤À̵ð - »ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC200~260V], [Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/8.3A], 100W, single, Waterproof, Cable, ALV, Cable, È¿À²:86%, 850g

75°³

1~1 : 19,800¿ø
2~9 : 19,600¿ø
10~19 : 19,400¿ø
20~49 : 19,200¿ø
50~99 : 18,600¿ø
100~299 : 18,200¿ø
̵̧
Á¦Ç°

À̺¥Æ®Áß


6

Á¦Ç°ÀÇ »ç¾ç

 INPUT

 Input Voltage Range

 Universal Input ( Min - 100 VAC, Nor - 220 VAC, Max - 240 VAC )

 Input Frequency Range

 Min - 50 Hz, Max - 60 Hz

 Input Current  100 VAC in, 100 W output ( Max - 1.3 A higher)
 Power Factor (Typical)  220 VAC, 110 VAC ( Min - 0.95, Max - 0.99 )
 Inrus Current  At 230 VAC VAC input, 25 ¡ÆC cold start ( Max - 40 A )

 OUTPUT

 Line Regulation

 Nor - ¡¾2%

 Load Regulation

 Nor - ¡¾2% 

 Voltage Accuracy

 % of Vout ( Nor - ¡¾5 % )

 Ripple and Noise

 20MHz Bandwidth ( Nor - 50 mV )

 Trun-on Delay  Measured at 220 VAC and full lod ( Nor - 1s )
 Short Circuit Protection  Auto Recovery
 Over Voltage Protection  Non-latching. See individual moldels OVP levels

GENERAL

 Isolation Voltage

 Input to Chassis ( Nor - 2000 VAC )

 Efficiency (Typical)  See individual models ( Nor - 83.0 % )
 No load Power Dissipation  Measured at 100VAC and 220VAC ( Nor - 1.0 W )
 Lifetime  Load 100 % at 30 ¡ÆC ( Nor - 40000 Hour )
 Weight  850 g
 Operating Temperature  Min. -20 ¡ÆC, Max. +50 ¡ÆC
 Storage Temperature  Min. -20 ¡ÆC, Max. +70 ¡ÆC
 Relative Humidity  Min. 10, Max 90 %RH
 Power Derating

 At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

 At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

EMC

 Emissions

 

 Conducted

 EN55015 ( Level B )

 Radiated  EN55015 ( Level B )
 Harmonic Distortion  EN61000-3-2 ( Compliant )
 Flicker and Fluctuation  EN61000-3-2 ( Compliant )
 Immunity  
 ESD  EN61000-4-2 ( Level 4 )
 Radiated RFI  EN61000-4-3 ( Level 3 )
 Fast Transients - burst  EN61000-4-4 ( Level 4 )
 Input Line Surges  EN61000-4-5 ( Level 4 )
 Conducted RFI  EN61000-4-6 ( Compliant )
 Power Freq Magnetic Field  EN61000-4-8 ( Compliant )
 Voltage Dips  EN61000-4-11 ( Compliant )

OTHERS

 Case size

 64 X 44 X 185 mm (WxHxD)

 Weight

 850 g


â´Ý±â
NCP100-PF-12 ¡¦ NCP Series [Á¦Á¶»ç:¿£¾¾¿¤À̵ð - »ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC90~240V], [Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/8.4A], 100W, single, Waterproof, Cable, ALV, Cable-PFC, È¿À²:86%, 850g

3°³

1~1 : 43,200¿ø
2~9 : 42,800¿ø
10~19 : 42,300¿ø
20~49 : 41,900¿ø
50~99 : 40,600¿ø
100~299 : 39,700¿ø
ÆÇ¸ÅÁß


5

Á¦Ç°ÀÇ »ç¾ç

 INPUT

 Input Voltage Range

 Min - 200 VAC, Nor - 220 VAC, Max - 260 VAC

 Input Frequency Range

 Nor - 60 Hz

 Input Current  220 VAC in, 150W output ( Max - 1.7 A )
 Power Factor  220 VAC
 Inrus Current  At 230 VAC VAC input, 25 ¡ÆC cold start ( Max - 50 A )

 OUTPUT

 Line Regulation

 Nor - ¡¾2%

 Load Regulation

 Nor - ¡¾2% 

 Voltage Accuracy

 % of Vout ( Nor - ¡¾5 % )

 Ripple and Noise

 20MHz Bandwidth ( Nor - 500 mV )

 Trun-on Delay  Measured at 220 VAC and full lod ( Nor - 1 s )
 Short Circuit Protection  Auto Recovery
 Over Voltage Protection  Non-latching. See individual moldels OVP levels

GENERAL

 Isolation Voltage

 Input to Chassis ( Nor - 2000 VAC )

 Efficiency (Typical)  See individual models ( Nor - 83.0 % )
 No load Power Dissipation  Measured at 100 VAC and 220 VAC ( Nor - 2.0 W )
 Lifetime  Load 100% at 30 ¡ÆC ( Nor - 40000 Hour )
 Weight  1300 g
 Operating Temperature  Min. -20 ¡ÆC, Max. +50 ¡ÆC
 Storage Temperature  Min. -20 ¡ÆC, Max. +70 ¡ÆC
 Relative Humidity  Min. 10, Max 90 %RH
 Power Derating

 At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

 At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

EMC

 Emissions

 

 Conducted

 EN55015 ( Level B )

 Radiated  EN55015 ( Level B )
 Harmonic Distortion  EN61000-3-2 ( Compliant )
 Flicker and Fluctuation  EN61000-3-2 ( Compliant )
 Immunity  
 ESD  EN61000-4-2 ( Level 4 )
 Radiated RFI  EN61000-4-3 ( Level 3 )
 Fast Transients - burst  EN61000-4-4 ( Level 4 )
 Input Line Surges  EN61000-4-5 ( Level 4 )
 Conducted RFI  EN61000-4-6 ( Compliant )
 Power Freq Magnetic Field  EN61000-4-8 ( Compliant )
 Voltage Dips  EN61000-4-11 ( Compliant )

OTHERS

 Case size

 92 X 46 X 193.4 mm (WxHxD)

 Weight

 1300 g


â´Ý±â
NCP150-NF-12 ¡¦ NCP Series [Á¦Á¶»ç:¿£¾¾¿¤À̵ð - »ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC200~260V], [Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/12.5A], 150W, single, Waterproof, Cable, ALV, Cable, È¿À²:88%, 1300g

50°³

1~1 : 28,400¿ø
2~9 : 28,100¿ø
10~19 : 27,800¿ø
20~49 : 27,500¿ø
50~99 : 26,700¿ø
100~299 : 26,100¿ø
ÆÇ¸ÅÁß


4

Á¦Ç°ÀÇ »ç¾ç

 INPUT

 Input Voltage Range

 Min - 200 VAC, Nor - 220 VAC, Max - 260 VAC

 Input Frequency Range

 Nor - 60 Hz

 Input Current  220 VAC in, 150W output ( Max - 1.7 A )
 Power Factor  220 VAC
 Inrus Current  At 230 VAC VAC input, 25 ¡ÆC cold start ( Max - 50 A )

 OUTPUT

 Line Regulation

 Nor - ¡¾2%

 Load Regulation

 Nor - ¡¾2% 

 Voltage Accuracy

 % of Vout ( Nor - ¡¾5 % )

 Ripple and Noise

 20MHz Bandwidth ( Nor - 500 mV )

 Trun-on Delay  Measured at 220 VAC and full lod ( Nor - 1 s )
 Short Circuit Protection  Auto Recovery
 Over Voltage Protection  Non-latching. See individual moldels OVP levels

GENERAL

 Isolation Voltage

 Input to Chassis ( Nor - 2000 VAC )

 Efficiency (Typical)  See individual models ( Nor - 83.0 % )
 No load Power Dissipation  Measured at 100 VAC and 220 VAC ( Nor - 2.0 W )
 Lifetime  Load 100% at 30 ¡ÆC ( Nor - 40000 Hour )
 Weight  1300 g
 Operating Temperature  Min. -20 ¡ÆC, Max. +50 ¡ÆC
 Storage Temperature  Min. -20 ¡ÆC, Max. +70 ¡ÆC
 Relative Humidity  Min. 10, Max 90 %RH
 Power Derating

 At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

 At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

EMC

 Emissions

 

 Conducted

 EN55015 ( Level B )

 Radiated  EN55015 ( Level B )
 Harmonic Distortion  EN61000-3-2 ( Compliant )
 Flicker and Fluctuation  EN61000-3-2 ( Compliant )
 Immunity  
 ESD  EN61000-4-2 ( Level 4 )
 Radiated RFI  EN61000-4-3 ( Level 3 )
 Fast Transients - burst  EN61000-4-4 ( Level 4 )
 Input Line Surges  EN61000-4-5 ( Level 4 )
 Conducted RFI  EN61000-4-6 ( Compliant )
 Power Freq Magnetic Field  EN61000-4-8 ( Compliant )
 Voltage Dips  EN61000-4-11 ( Compliant )

OTHERS

 Case size

 92 X 46 X 193.4 mm (WxHxD)

 Weight

 1300 g


â´Ý±â
NCP150-NF-24 ¡¦ NCP Series [Á¦Á¶»ç:¿£¾¾¿¤À̵ð - »ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC200~260V], [Ãâ·ÂÀü¾Ð/Àü·ùCH1: 24V/6.25A], 150W, single, Waterproof, Cable, ALV, Cable, È¿À²:90%, 1300g

46°³

1~1 : 28,400¿ø
2~9 : 28,100¿ø
10~19 : 27,800¿ø
20~49 : 27,500¿ø
50~99 : 26,700¿ø
100~299 : 26,100¿ø
ÆÇ¸ÅÁß


3

Á¦Ç°ÀÇ »ç¾ç

 INPUT

 Input Voltage Range

 Min - 200 VAC, Nor - 220 VAC, Max - 260 VAC

 Input Frequency Range

 Nor - 60 Hz

 Input Current  220 VAC in, 200W output ( Max - 2.3 A )
 Power Factor  220 VAC
 Inrus Current  At 230 VAC VAC input, 25 ¡ÆC cold start ( Nor - 50 A )

 OUTPUT

 Line Regulation

 Nor - ¡¾2%

 Load Regulation

 Nor - ¡¾2% 

 Voltage Accuracy

 % of Vout ( Nor - ¡¾5 % )

 Ripple and Noise

 20MHz Bandwidth ( Nor - 500 mV )

 Trun-on Delay  Measured at 220VAC and full lod ( Nor - 1 s )
 Short Circuit Protection  Auto Recovery
 Over Voltage Protection  Non-latching. See individual moldels OVP levels

GENERAL

 Isolation Voltage

 Input to Chassis ( Nor - 2000 VAC )

 Efficiency (Typical)  See individual models ( Nor - 86.0 % )
 No load Power Dissipation  Measured at 100 VAC and 220 VAC ( Nor - 2.0 W )
 Lifetime  Load 100% at 30 ¡ÆC ( Nor - 32000 Hour )
 Weight  1300 g
 Operating Temperature  Min. -20 ¡ÆC, Max. +50 ¡ÆC
 Storage Temperature  Min. -20 ¡ÆC, Max. +70 ¡ÆC
 Relative Humidity  Min. 10, Max 90 %RH
 Power Derating

 At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

 At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

EMC

 Emissions

 

 Conducted

 EN55015 ( Level B )

 Radiated  EN55015 ( Level B )
 Harmonic Distortion  EN61000-3-2 ( Compliant )
 Flicker and Fluctuation  EN61000-3-2 ( Compliant )
 Immunity  
 ESD  EN61000-4-2 ( Level 4 )
 Radiated RFI  EN61000-4-3 ( Level 3 )
 Fast Transients - burst  EN61000-4-4 ( Level 4 )
 Input Line Surges  EN61000-4-5 ( Level 4 )
 Conducted RFI  EN61000-4-6 ( Compliant )
 Power Freq Magnetic Field  EN61000-4-8 ( Compliant )
 Voltage Dips  EN61000-4-11 ( Compliant )

OTHERS

 Case size

 92 X 46 X 213.4 mm (WxHxD)

 Weight

 1300 g


â´Ý±â
NCP200-NF-12 ¡¦ NCP Series [Á¦Á¶»ç:¿£¾¾¿¤À̵ð - »ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC200~260V], [Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/15.8A], 200W, single, Waterproof, Cable, ALV, Cable, È¿À²:88%, 1300g

48°³

1~1 : 31,100¿ø
2~9 : 30,800¿ø
10~19 : 30,500¿ø
20~49 : 30,200¿ø
50~99 : 29,200¿ø
100~299 : 28,600¿ø
ÆÇ¸ÅÁß


2

Á¦Ç°ÀÇ »ç¾ç

 INPUT

 Input Voltage Range

 Universal Input ( Min - 100 VAC, Nor - 220 VAC, Max - 240 VAC )

 Input Frequency Range

 Min - 50 Hz, Max - 60 Hz

 Input Current  100 VAC in, 200 W output ( Max - 2.1 A higher )
 Power Factor (Typical)  220 VAC, 110 VAC ( Min - 0.95, Max - 0.99 )
 Inrus Current  At 230VAC VAC input, 25 ¡ÆC cold start ( Max - 30 A )

 OUTPUT

 Line Regulation

 Nor - ¡¾2%

 Load Regulation

 Nor - ¡¾2% 

 Voltage Accuracy

 % of Vout ( Nor - ¡¾5 % )

 Ripple and Noise

 20MHz Bandwidth ( Nor - 500 mV )

 Trun-on Delay  Measured at 220VAC and full lod ( Nor - 1.5 s )
 Short Circuit Protection  Auto Recovery
 Over Voltage Protection  Non-latching. See individual moldels OVP levels

GENERAL

 Isolation Voltage

 Input to Chassis ( Nor - 2000 VAC )

 Efficiency (Typical)  See individual models ( Nor - 86.0% )
 No load Power Dissipation  Measured at 100 VAC and 220 VAC ( Nor - 2.0 W )
 Lifetime  Load 100 % at 30 ¡ÆC ( Nor - 32000 Hour )
 Weight  1300 g
 Operating Temperature  Min. -20 ¡ÆC, Max. +50 ¡ÆC
 Storage Temperature  Min. -20 ¡ÆC, Max. +70 ¡ÆC
 Relative Humidity  Min. 10, Max 90 %RH
 Power Derating

 At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

 At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

EMC

 Emissions

 

 Conducted

 EN55015 ( Level B )

 Radiated  EN55015 ( Level B )
 Harmonic Distortion  EN61000-3-2 ( Compliant )
 Flicker and Fluctuation  EN61000-3-2 ( Compliant )
 Immunity  
 ESD  EN61000-4-2 ( Level 4 )
 Radiated RFI  EN61000-4-3 ( Level 3 )
 Fast Transients - burst  EN61000-4-4 ( Level 4 )
 Input Line Surges  EN61000-4-5 ( Level 4 )
 Conducted RFI  EN61000-4-6 ( Compliant )
 Power Freq Magnetic Field  EN61000-4-8 ( Compliant )
 Voltage Dips  EN61000-4-11 ( Compliant )

OTHERS

 Case size

 78 X 46 X 213.4 mm (WxHxD)

 Weight

 1300 g


â´Ý±â
NCP200-PF-12 ¡¦ NCP Series [Á¦Á¶»ç:¿£¾¾¿¤À̵ð - »ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC90~240V], [Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/15A], 200W, single, Waterproof, Cable, ALV, Cable-PFC, È¿À²:88%, 1300g

0°³

1~1 : 52,000¿ø
2~9 : 51,500¿ø
10~19 : 51,000¿ø
20~49 : 50,400¿ø
50~99 : 48,900¿ø
100~299 : 47,800¿ø
ÆÇ¸ÅÁß
À̺¥Æ®Áß


1

Á¦Ç°ÀÇ »ç¾ç

 INPUT

 Input Voltage Range

 Min - 200 VAC, Nor - 220 VAC, Max - 260 VAC

 Input Frequency Range

 Nor - 60 Hz

 Input Current  220 VAC in, 300 W output ( Max - 2.9 A )
 Power Factor  220 VAC ( Nor - 0.55 )
 Inrus Current  At 220 VAC VAC input, 25 ¡ÆC cold start ( Max - 50 A )

 OUTPUT

 Line Regulation

 Nor - ¡¾2%

 Load Regulation

 Nor - ¡¾2% 

 Voltage Accuracy

 % of Vout ( Nor - ¡¾5 % )

 Ripple and Noise

 20MHz Bandwidth ( Nor - 500 mV )

 Trun-on Delay  Measured at 220VAC and full lod ( Nor - 1 s )
 Short Circuit Protection  Auto Recovery
 Over Voltage Protection  Non-latching. See individual moldels OVP levels

GENERAL

 Isolation Voltage

 Input to Chassis ( Nor - 2000 VAC )

 Efficiency (Typical)  See individual models ( Nor - 86.0 % )
 No load Power Dissipation  Measured at 100 VAC and 220 VAC ( Nor - 2.0 W )
 Lifetime  Load 100 % at 30 ¡ÆC ( Nor - 32000 Hour )
 Weight  2000 g
 Operating Temperature  Min. -20 ¡ÆC, Max. +50 ¡ÆC
 Storage Temperature  Min. -20 ¡ÆC, Max. +70 ¡ÆC
 Relative Humidity  Min. 10, Max 90 %RH
 Power Derating

 At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

 At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC

EMC

 Emissions

 

 Conducted

 EN55015 ( Level B )

 Radiated  EN55015 ( Level B )
 Harmonic Distortion  EN61000-3-2 ( Compliant )
 Flicker and Fluctuation  EN61000-3-2 ( Compliant )
 Immunity  
 ESD  EN61000-4-2 ( Level 4 )
 Radiated RFI  EN61000-4-3 ( Level 3 )
 Fast Transients - burst  EN61000-4-4 ( Level 4 )
 Input Line Surges  EN61000-4-5 ( Level 4 )
 Conducted RFI  EN61000-4-6 ( Compliant )
 Power Freq Magnetic Field  EN61000-4-8 ( Compliant )
 Voltage Dips  EN61000-4-11 ( Compliant )

OTHERS

 Case size

 110 X 46 X 243.4 mm (WxHxD)

 Weight

 2000 g


â´Ý±â
NCP300-NF-12 ¡¦ NCP Series [Á¦Á¶»ç:¿£¾¾¿¤À̵ð - »ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC200~260V], [Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/22A], 300W, single, Waterproof, Cable, ALV, Cable, È¿À²:88%, 2000g

29°³

1~1 : 39,200¿ø
2~9 : 38,800¿ø
10~19 : 38,400¿ø
20~49 : 38,000¿ø
50~99 : 36,800¿ø
100~299 : 36,100¿ø
ÆÇ¸ÅÁß


[1]