¡Å 23 °³ÀÇ Á¦Ç°ÀÌ °Ë»öµÇ¾ú½À´Ï´Ù. |
|
|
No |
À̹ÌÁö |
Á¦Ç°¼³¸í ¡ØÀÎÁõ¼º¸±â ÀÎÁõ¸¶Å© Ŭ¸¯¡Ø |
Àç°í |
ÀÚ·á |
¼ö·®°¡°Ý (VATº°µµ) |
ºÐ·ù |
±¸¸Å |
23

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Min - 200 VAC, Nor - 220 VAC, Max - 260 VAC |
Input Frequency Range |
Nor - 60 Hz |
Input Current |
220 VAC in, 30 W output |
Power Factor (Typical) |
220 VAC |
Inrus Current |
At 230 VAC VAC input, 25 ¡ÆC cold start |
OUTPUT |
Line Regulation |
Nor - ¡¾2% |
Load Regulation |
Nor - ¡¾2% |
Voltage Accuracy |
% of Vout ( Nor - ¡¾5 % ) |
Ripple and Noise |
20MHz Bandwidth ( Nor - 500 mV ) |
Trun-on Delay |
Measured at 220 VAC and full lod ( Nor - 1s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 3000 VAC ) |
Efficiency (Typical) |
See individual models |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 1.0 W ) |
Lifetime |
Load 100% at 30 ¡ÆC ( Nor - 40000 Hour ) |
Weight |
170 g |
Operating Temperature |
Min. -30 ¡ÆC, Max. +50 ¡ÆC |
Storage Temperature |
Min. -30 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
26x20x178 mm (WxHxD) |
Weight |
170 g |
â´Ý±â
|
|
NCP30-NF-12 ¡¦
NCP Series
[Á¦Á¶»ç:¿£¾¾¿¤À̵ð -
»ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC200~260V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/2.5A],
30W,
single,
Waterproof,
Cable,
ALV,
Cable,
È¿À²:83%,
170g
|
0°³
|

|
1~1 : |
8,200¿ø
|
2~9 : |
8,100¿ø
|
10~19 : |
8,000¿ø
|
20~49 : |
8,000¿ø
|
50~99 : |
7,700¿ø
|
100~299 : |
7,500¿ø
|
|
ÆÇ¸ÅÁß
À̺¥Æ®Áß
|
|
22

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Min - 200 VAC, Nor - 220 VAC, Max - 260 VAC |
Input Frequency Range |
Nor - 60 Hz |
Input Current |
100W input 0.34A |
Power Factor (Typical) |
None PFC |
Inrus Current |
At 220 VAC VAC input, 25 ¡ÆC cold start |
OUTPUT |
Line Regulation |
220Vac Full load |
Load Regulation |
220Vac Full load |
Voltage Accuracy |
% of Vout ( Nor - ¡¾2 % ) |
Ripple and Noise |
20MHz Bandwidth ( Nor - 500 mV ) |
Trun-on Delay |
Measured at 220 VAC and full lod ( Nor - 2s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 3000 VAC ) |
Efficiency (Typical) |
See individual models |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 1.0 W ) |
Lifetime |
Load 100% at 30 ¡ÆC ( Nor - 40000 Hour ) |
Weight |
170 g |
Operating Temperature |
Min. -20 ¡ÆC, Max. +50 ¡ÆC |
Storage Temperature |
Min. -30 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
28x20x180 mm (WxHxD) |
Weight |
170 g |
â´Ý±â
|
|
HM30-NF-12 ¡¦
HMS Series
[Á¦Á¶»ç:Çö¹Î -
»ý»ê±¹:Korea]
[ÀÔ·ÂÀü¾Ð: AC200~260V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/2.2A],
30W,
single,
Waterproof,
Cable,
Cable,
È¿À²:86%,
170g
|
48°³
|

|
1~1 : |
8,200¿ø
|
2~9 : |
8,100¿ø
|
10~19 : |
8,000¿ø
|
20~49 : |
8,000¿ø
|
50~99 : |
7,700¿ø
|
100~299 : |
7,500¿ø
|
|
Ãßõ Á¦Ç°
À̺¥Æ®Áß
|
|
21

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Min - 200 VAC, Nor - 220 VAC, Max - 260 VAC |
Input Frequency Range |
Nor - 60 Hz |
Input Current |
220 VAC in, 60 W output ( Max - 0.72 A ) |
Power Factor (Typical) |
220 VAC |
Inrus Current |
At 230 VAC VAC input, 25 ¡ÆC cold start ( Max - 40 A ) |
OUTPUT |
Line Regulation |
Nor - ¡¾2% |
Load Regulation |
Nor - ¡¾2% |
Voltage Accuracy |
% of Vout ( Nor - ¡¾5 % ) |
Ripple and Noise |
20MHz Bandwidth ( Nor - 500 mV ) |
Trun-on Delay |
Measured at 220 VAC and full lod ( Nor - 1s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 3000 VAC ) |
Efficiency (Typical) |
See individual models ( Nor - 83.0% ) |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 1.0 W ) |
Lifetime |
Load 100% at 30 ¡ÆC ( Nor - 40000 Hour ) |
Weight |
330 g |
Operating Temperature |
Min. -30 ¡ÆC, Max. +50 ¡ÆC |
Storage Temperature |
Min. -30 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
44.4 X 36.4 X 160.5 mm (WxHxD) |
Weight |
330 g |
â´Ý±â
|
|
NCP60-NF-12 ¡¦
NCP Series
[Á¦Á¶»ç:¿£¾¾¿¤À̵ð -
»ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC200~260V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/5A],
60W,
single,
Waterproof,
Cable,
ALV,
Cable,
È¿À²:85%,
330g
|
0°³
|


|
1~1 : |
13,200¿ø
|
2~9 : |
13,100¿ø
|
10~19 : |
12,900¿ø
|
20~49 : |
12,800¿ø
|
50~99 : |
12,400¿ø
|
100~299 : |
12,100¿ø
|
|
Ãßõ Á¦Ç°
À̺¥Æ®Áß
|
|
20

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Universal Input ( Min - 100 VAC, Nor - 220 VAC, Max - 240 VAC ) |
Input Frequency Range |
Min - 50 Hz, Max - 60 Hz |
Input Current |
100 VAC in, 60 W output ( Max - 0.8 A higher) |
Power Factor (Typical) |
220 VAC, 110 VAC ( Min - 0.95, Max - 0.98 ) |
Inrus Current |
At 230 VAC VAC input, 25 ¡ÆC cold start ( Max - 40 A ) |
OUTPUT |
Line Regulation |
Nor - ¡¾2% |
Load Regulation |
Nor - ¡¾2% |
Voltage Accuracy |
% of Vout ( Nor - ¡¾5 % ) |
Ripple and Noise |
20MHz Bandwidth ( Nor - 500 mV ) |
Trun-on Delay |
Measured at 220 VAC and full lod ( Nor - 1s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 3000 VAC ) |
Efficiency (Typical) |
See individual models ( Nor - 83.0% ) |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 1.0 W ) |
Lifetime |
Load 100% at 30 ¡ÆC ( Nor - 40000 Hour ) |
Weight |
330 g |
Operating Temperature |
Min. -30 ¡ÆC, Max. +50 ¡ÆC |
Storage Temperature |
Min. -30 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
44.4 X 36.4 X 160.5 mm (WxHxD) |
Weight |
330 g |
â´Ý±â
|
|
NCP60-PF-12 ¡¦
NCP Series
[Á¦Á¶»ç:¿£¾¾¿¤À̵ð -
»ý»ê±¹:Korea]
[ÀÔ·ÂÀü¾Ð: AC90~240V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/5A],
60W,
single,
Waterproof,
Cable,
ALV,
Cable-PFC,
È¿À²:85%,
330g
|
19°³
|


|
1~1 : |
23,000¿ø
|
2~9 : |
22,800¿ø
|
10~19 : |
22,500¿ø
|
20~49 : |
22,300¿ø
|
50~99 : |
21,600¿ø
|
100~299 : |
21,200¿ø
|
|
ÆÇ¸ÅÁß
|
|
19

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Min - 200 VAC, Nor - 220 VAC, Max - 260 VAC |
Input Frequency Range |
Nor - 60 Hz |
Input Current |
100W input 0.81A |
Power Factor (Typical) |
None PFC |
Inrus Current |
At 220 VAC VAC input, 25 ¡ÆC cold start |
OUTPUT |
Line Regulation |
220Vac Full load |
Load Regulation |
220Vac Full load(¡¾2 %) |
Voltage Accuracy |
% of Vout ( Nor - ¡¾2 % ) |
Ripple and Noise |
20MHz Bandwidth ( 500 mV ) |
Trun-on Delay |
Measured at 220 VAC and full lod ( Nor - 2s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 3000 VAC ) |
Efficiency (Typical) |
See individual models |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 1.0 W ) |
Lifetime |
Load 100% at 30 ¡ÆC ( Nor - 40000 Hour ) |
Weight |
1170 g |
Operating Temperature |
Min. -20 ¡ÆC, Max. +50 ¡ÆC |
Storage Temperature |
Min. -30 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
52x32x182 mm (WxHxD) |
Weight |
1170 g |
â´Ý±â
|
|
HM100-NF-12 ¡¦
HM Series
[Á¦Á¶»ç:Çö¹Î -
»ý»ê±¹:Korea]
[ÀÔ·ÂÀü¾Ð: AC180~240V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/7.5A],
100W,
single,
Waterproof,
Cable,
Cable,
È¿À²:86%,
1170g
|
34°³
|

|
1~1 : |
19,800¿ø
|
2~9 : |
19,600¿ø
|
10~19 : |
19,400¿ø
|
20~49 : |
19,200¿ø
|
50~99 : |
18,600¿ø
|
100~299 : |
18,200¿ø
|
|
ÆÇ¸ÅÁß
À̺¥Æ®Áß
|
|
18

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Min - 200 VAC, Nor - 220 VAC, Max - 260 VAC |
Input Frequency Range |
Nor - 60 Hz |
Input Current |
100W input 0.7A |
Power Factor (Typical) |
None PFC |
Inrus Current |
At 220 VAC VAC input, 25 ¡ÆC cold start |
OUTPUT |
Line Regulation |
220Vac Full load |
Load Regulation |
220Vac Full load(¡¾2 %) |
Voltage Accuracy |
% of Vout ( Nor - ¡¾2 % ) |
Ripple and Noise |
20MHz Bandwidth ( 500 mV ) |
Trun-on Delay |
Measured at 220 VAC and full lod ( Nor - 2s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 3000 VAC ) |
Efficiency (Typical) |
See individual models |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 1.0 W ) |
Lifetime |
Load 100% at 30 ¡ÆC ( Nor - 40000 Hour ) |
Weight |
1170 g |
Operating Temperature |
Min. -20 ¡ÆC, Max. +50 ¡ÆC |
Storage Temperature |
Min. -30 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
52x32x182 mm (WxHxD) |
Weight |
1170 g |
â´Ý±â
|
|
HM100-NF-24 ¡¦
HM Series
[Á¦Á¶»ç:Çö¹Î -
»ý»ê±¹:Korea]
[ÀÔ·ÂÀü¾Ð: AC180~240V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 24V/3.6A],
100W,
single,
Waterproof,
Cable,
Cable,
È¿À²:86%,
1170g
|
0°³
|

|
1~1 : |
21,000¿ø
|
2~9 : |
20,800¿ø
|
10~19 : |
20,600¿ø
|
20~49 : |
20,400¿ø
|
50~99 : |
19,700¿ø
|
100~299 : |
19,300¿ø
|
|
ÆÇ¸ÅÁß
|
|
17

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Nor - 220 VAC |
Input Frequency Range |
Nor - 60 Hz |
Input Current |
100 VAC in, 100 W output ( Max - 1.2 A ) |
Power Factor (Typical) |
|
Inrus Current |
At 230 VAC VAC input, 25 ¡ÆC cold start ( Max - 40 A ) |
OUTPUT |
Line Regulation |
Nor - ¡¾2% |
Load Regulation |
Nor - ¡¾2% |
Voltage Accuracy |
% of Vout ( Nor - ¡¾5 % ) |
Ripple and Noise |
20MHz Bandwidth ( Nor - 500 mV ) |
Trun-on Delay |
Measured at 220 VAC and full lod ( Nor - 1s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 2000 VAC ) |
Efficiency (Typical) |
See individual models ( Nor - 83.0% ) |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 1.0 W ) |
Lifetime |
Load 100% at 30 ¡ÆC ( Nor - 40000 Hour ) |
Weight |
850 g |
Operating Temperature |
Min. -20 ¡ÆC, Max. +50 ¡ÆC |
Storage Temperature |
Min. -20 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
78 X 44 X 165 mm (WxHxD) |
Weight |
850 g |
â´Ý±â
|
|
NCP100-NF-12 ¡¦
NCP Series
[Á¦Á¶»ç:¿£¾¾¿¤À̵ð -
»ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC200~260V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/8.3A],
100W,
single,
Waterproof,
Cable,
ALV,
Cable,
È¿À²:86%,
850g
|
75°³
|


|
1~1 : |
19,800¿ø
|
2~9 : |
19,600¿ø
|
10~19 : |
19,400¿ø
|
20~49 : |
19,200¿ø
|
50~99 : |
18,600¿ø
|
100~299 : |
18,200¿ø
|
|
Ãßõ Á¦Ç°
À̺¥Æ®Áß
|
|
16

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Universal Input ( Min - 100 VAC, Nor - 220 VAC, Max - 240 VAC ) |
Input Frequency Range |
Min - 50 Hz, Max - 60 Hz |
Input Current |
100 VAC in, 100 W output ( Max - 1.3 A higher) |
Power Factor (Typical) |
220 VAC, 110 VAC ( Min - 0.95, Max - 0.99 ) |
Inrus Current |
At 230 VAC VAC input, 25 ¡ÆC cold start ( Max - 40 A ) |
OUTPUT |
Line Regulation |
Nor - ¡¾2% |
Load Regulation |
Nor - ¡¾2% |
Voltage Accuracy |
% of Vout ( Nor - ¡¾5 % ) |
Ripple and Noise |
20MHz Bandwidth ( Nor - 50 mV ) |
Trun-on Delay |
Measured at 220 VAC and full lod ( Nor - 1s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 2000 VAC ) |
Efficiency (Typical) |
See individual models ( Nor - 83.0 % ) |
No load Power Dissipation |
Measured at 100VAC and 220VAC ( Nor - 1.0 W ) |
Lifetime |
Load 100 % at 30 ¡ÆC ( Nor - 40000 Hour ) |
Weight |
850 g |
Operating Temperature |
Min. -20 ¡ÆC, Max. +50 ¡ÆC |
Storage Temperature |
Min. -20 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
64 X 44 X 185 mm (WxHxD) |
Weight |
850 g |
â´Ý±â
|
|
NCP100-PF-12 ¡¦
NCP Series
[Á¦Á¶»ç:¿£¾¾¿¤À̵ð -
»ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC90~240V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/8.4A],
100W,
single,
Waterproof,
Cable,
ALV,
Cable-PFC,
È¿À²:86%,
850g
|
3°³
|


|
1~1 : |
43,200¿ø
|
2~9 : |
42,800¿ø
|
10~19 : |
42,300¿ø
|
20~49 : |
41,900¿ø
|
50~99 : |
40,600¿ø
|
100~299 : |
39,700¿ø
|
|
ÆÇ¸ÅÁß
|
|
15

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Min - 200 VAC, Nor - 220 VAC, Max - 260 VAC |
Input Frequency Range |
Nor - 60 Hz |
Input Current |
220 VAC in, 150W output ( Max - 1.7 A ) |
Power Factor |
220 VAC |
Inrus Current |
At 230 VAC VAC input, 25 ¡ÆC cold start ( Max - 50 A ) |
OUTPUT |
Line Regulation |
Nor - ¡¾2% |
Load Regulation |
Nor - ¡¾2% |
Voltage Accuracy |
% of Vout ( Nor - ¡¾5 % ) |
Ripple and Noise |
20MHz Bandwidth ( Nor - 500 mV ) |
Trun-on Delay |
Measured at 220 VAC and full lod ( Nor - 1 s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 2000 VAC ) |
Efficiency (Typical) |
See individual models ( Nor - 83.0 % ) |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 2.0 W ) |
Lifetime |
Load 100% at 30 ¡ÆC ( Nor - 40000 Hour ) |
Weight |
1300 g |
Operating Temperature |
Min. -20 ¡ÆC, Max. +50 ¡ÆC |
Storage Temperature |
Min. -20 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
92 X 46 X 193.4 mm (WxHxD) |
Weight |
1300 g |
â´Ý±â
|
|
NCP150-NF-12 ¡¦
NCP Series
[Á¦Á¶»ç:¿£¾¾¿¤À̵ð -
»ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC200~260V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/12.5A],
150W,
single,
Waterproof,
Cable,
ALV,
Cable,
È¿À²:88%,
1300g
|
50°³
|


|
1~1 : |
28,400¿ø
|
2~9 : |
28,100¿ø
|
10~19 : |
27,800¿ø
|
20~49 : |
27,500¿ø
|
50~99 : |
26,700¿ø
|
100~299 : |
26,100¿ø
|
|
ÆÇ¸ÅÁß
|
|
14

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Min - 200 VAC, Nor - 220 VAC, Max - 240 VAC |
Input Frequency Range |
Nor - 60 Hz |
Input Current |
150W input 1.35A |
Power Factor (Typical) |
None PFC |
Inrush Current |
At 220 VAC VAC input, 25 ¡ÆC cold start 30A |
OUTPUT |
Line Regulation |
220Vac Full load (¡¾5 %) |
Load Regulation |
220Vac Full load (¡¾5 %) |
Voltage Accuracy |
% of Vout ( Nor - ¡¾5 % ) |
Ripple and Noise |
20MHz Bandwidth ( 500 mV ) |
Trun-on Delay |
Measured at 220 VAC and full lod ( Nor - 2s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 3000 VAC ) |
Efficiency (Typical) |
See individual models |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 1.0 W ) |
Lifetime |
Load 100% at 30 ¡ÆC ( Nor - 40000 Hour ) |
Weight |
1170 g |
Operating Temperature |
Min. -20 ¡ÆC, Max. +40 ¡ÆC |
Storage Temperature |
Min. -30 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
52x32x182 mm (WxHxD) |
Weight |
1170 g |
â´Ý±â
|
|
HM150-NF-12 ¡¦
HM Series
[Á¦Á¶»ç:Çö¹Î -
»ý»ê±¹:Korea]
[ÀÔ·ÂÀü¾Ð: AC180~240V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/10A],
150W,
single,
Waterproof,
Cable,
Cable,
È¿À²:80%,
1170g
|
25°³
|

|
1~1 : |
28,400¿ø
|
2~9 : |
28,100¿ø
|
10~19 : |
27,800¿ø
|
20~49 : |
27,500¿ø
|
50~99 : |
26,700¿ø
|
100~299 : |
26,100¿ø
|
|
ÆÇ¸ÅÁß
|
|
13

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Min - 200 VAC, Nor - 220 VAC, Max - 260 VAC |
Input Frequency Range |
Nor - 60 Hz |
Input Current |
220 VAC in, 150W output ( Max - 1.7 A ) |
Power Factor |
220 VAC |
Inrus Current |
At 230 VAC VAC input, 25 ¡ÆC cold start ( Max - 50 A ) |
OUTPUT |
Line Regulation |
Nor - ¡¾2% |
Load Regulation |
Nor - ¡¾2% |
Voltage Accuracy |
% of Vout ( Nor - ¡¾5 % ) |
Ripple and Noise |
20MHz Bandwidth ( Nor - 500 mV ) |
Trun-on Delay |
Measured at 220 VAC and full lod ( Nor - 1 s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 2000 VAC ) |
Efficiency (Typical) |
See individual models ( Nor - 83.0 % ) |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 2.0 W ) |
Lifetime |
Load 100% at 30 ¡ÆC ( Nor - 40000 Hour ) |
Weight |
1300 g |
Operating Temperature |
Min. -20 ¡ÆC, Max. +50 ¡ÆC |
Storage Temperature |
Min. -20 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
92 X 46 X 193.4 mm (WxHxD) |
Weight |
1300 g |
â´Ý±â
|
|
NCP150-NF-24 ¡¦
NCP Series
[Á¦Á¶»ç:¿£¾¾¿¤À̵ð -
»ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC200~260V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 24V/6.25A],
150W,
single,
Waterproof,
Cable,
ALV,
Cable,
È¿À²:90%,
1300g
|
46°³
|


|
1~1 : |
28,400¿ø
|
2~9 : |
28,100¿ø
|
10~19 : |
27,800¿ø
|
20~49 : |
27,500¿ø
|
50~99 : |
26,700¿ø
|
100~299 : |
26,100¿ø
|
|
ÆÇ¸ÅÁß
|
|
12

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Min - 200 VAC, Nor - 220 VAC, Max - 260 VAC |
Input Frequency Range |
Nor - 60 Hz |
Input Current |
220 VAC in, 200W output ( Max - 2.3 A ) |
Power Factor |
220 VAC |
Inrus Current |
At 230 VAC VAC input, 25 ¡ÆC cold start ( Nor - 50 A ) |
OUTPUT |
Line Regulation |
Nor - ¡¾2% |
Load Regulation |
Nor - ¡¾2% |
Voltage Accuracy |
% of Vout ( Nor - ¡¾5 % ) |
Ripple and Noise |
20MHz Bandwidth ( Nor - 500 mV ) |
Trun-on Delay |
Measured at 220VAC and full lod ( Nor - 1 s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 2000 VAC ) |
Efficiency (Typical) |
See individual models ( Nor - 86.0 % ) |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 2.0 W ) |
Lifetime |
Load 100% at 30 ¡ÆC ( Nor - 32000 Hour ) |
Weight |
1300 g |
Operating Temperature |
Min. -20 ¡ÆC, Max. +50 ¡ÆC |
Storage Temperature |
Min. -20 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
92 X 46 X 213.4 mm (WxHxD) |
Weight |
1300 g |
â´Ý±â
|
|
NCP200-NF-12 ¡¦
NCP Series
[Á¦Á¶»ç:¿£¾¾¿¤À̵ð -
»ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC200~260V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/15.8A],
200W,
single,
Waterproof,
Cable,
ALV,
Cable,
È¿À²:88%,
1300g
|
48°³
|


|
1~1 : |
31,100¿ø
|
2~9 : |
30,800¿ø
|
10~19 : |
30,500¿ø
|
20~49 : |
30,200¿ø
|
50~99 : |
29,200¿ø
|
100~299 : |
28,600¿ø
|
|
ÆÇ¸ÅÁß
|
|
11

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Min - 180 VAC, Nor - 220 VAC, Max - 240 VAC |
Input Frequency Range |
Nor - 60 Hz |
Input Current |
1.4A |
Power Factor (Typical) |
None PFC |
Inrus Current |
At 220 VAC VAC input, 25 ¡ÆC cold start |
OUTPUT |
Line Regulation |
220Vac Full load (¡¾2 %) |
Load Regulation |
220Vac Full load (¡¾2 %) |
Voltage Accuracy |
% of Vout ( Nor - ¡¾5 % ) |
Ripple and Noise |
20MHz Bandwidth ( 500 mV ) |
Trun-on Delay |
Measured at 220 VAC and full lod ( Nor - 2s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 3000 VAC ) |
Efficiency (Typical) |
See individual models |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 1.0 W ) |
Lifetime |
Load 100% at 30 ¡ÆC ( Nor - 32,000 Hour ) |
Weight |
1170 g |
Operating Temperature |
Min. -20 ¡ÆC, Max. +40 ¡ÆC |
Storage Temperature |
Min. -30 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
75.2x46.9x228 mm (WxHxD) |
Weight |
1170 g |
â´Ý±â
|
|
HM200-NF-12 ¡¦
HM Series
[Á¦Á¶»ç:Çö¹Î -
»ý»ê±¹:Korea]
[ÀÔ·ÂÀü¾Ð: AC180~240V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/16.3A],
200W,
single,
Waterproof,
Cable,
Cable,
È¿À²:86%,
1170g
|
49°³
|

|
1~1 : |
31,100¿ø
|
2~9 : |
30,800¿ø
|
10~19 : |
30,500¿ø
|
20~49 : |
30,200¿ø
|
50~99 : |
29,200¿ø
|
100~299 : |
28,600¿ø
|
|
ÆÇ¸ÅÁß
|
|
10

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Min - 180 VAC, Nor - 220 VAC, Max - 240 VAC |
Input Frequency Range |
Nor - 60 Hz |
Input Current |
1.8A |
Power Factor (Typical) |
None PFC |
Inrus Current |
At 220 VAC VAC input, 25 ¡ÆC cold start (40A) |
OUTPUT |
Line Regulation |
220Vac Full load (¡¾2 %) |
Load Regulation |
220Vac Full load (¡¾2 %) |
Voltage Accuracy |
% of Vout ( Nor - ¡¾5 % ) |
Ripple and Noise |
20MHz Bandwidth ( 500 mV ) |
Trun-on Delay |
Measured at 220 VAC and full lod ( Nor - 2s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 3000 VAC ) |
Efficiency (Typical) |
See individual models |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 1.0 W ) |
Lifetime |
Load 100% at 30 ¡ÆC ( Nor - 32,000 Hour ) |
Weight |
1170 g |
Operating Temperature |
Min. -20 ¡ÆC, Max. +40 ¡ÆC |
Storage Temperature |
Min. -30 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
75.2x46.9x228 mm (WxHxD) |
Weight |
1170 g |
â´Ý±â
|
|
HM200-NF-24 ¡¦
HM Series
[Á¦Á¶»ç:Çö¹Î -
»ý»ê±¹:Korea]
[ÀÔ·ÂÀü¾Ð: AC180~240V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 24V/8A],
200W,
single,
Waterproof,
Cable,
Cable,
È¿À²:86%,
1170g
|
50°³
|

|
1~1 : |
31,100¿ø
|
2~9 : |
30,800¿ø
|
10~19 : |
30,500¿ø
|
20~49 : |
30,200¿ø
|
50~99 : |
29,200¿ø
|
100~299 : |
28,600¿ø
|
|
ÆÇ¸ÅÁß
|
|
9

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Universal Input ( Min - 100 VAC, Nor - 220 VAC, Max - 240 VAC ) |
Input Frequency Range |
Min - 50 Hz, Max - 60 Hz |
Input Current |
100 VAC in, 200 W output ( Max - 2.1 A higher ) |
Power Factor (Typical) |
220 VAC, 110 VAC ( Min - 0.95, Max - 0.99 ) |
Inrus Current |
At 230VAC VAC input, 25 ¡ÆC cold start ( Max - 30 A ) |
OUTPUT |
Line Regulation |
Nor - ¡¾2% |
Load Regulation |
Nor - ¡¾2% |
Voltage Accuracy |
% of Vout ( Nor - ¡¾5 % ) |
Ripple and Noise |
20MHz Bandwidth ( Nor - 500 mV ) |
Trun-on Delay |
Measured at 220VAC and full lod ( Nor - 1.5 s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 2000 VAC ) |
Efficiency (Typical) |
See individual models ( Nor - 86.0% ) |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 2.0 W ) |
Lifetime |
Load 100 % at 30 ¡ÆC ( Nor - 32000 Hour ) |
Weight |
1300 g |
Operating Temperature |
Min. -20 ¡ÆC, Max. +50 ¡ÆC |
Storage Temperature |
Min. -20 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
78 X 46 X 213.4 mm (WxHxD) |
Weight |
1300 g |
â´Ý±â
|
|
NCP200-PF-12 ¡¦
NCP Series
[Á¦Á¶»ç:¿£¾¾¿¤À̵ð -
»ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC90~240V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/15A],
200W,
single,
Waterproof,
Cable,
ALV,
Cable-PFC,
È¿À²:88%,
1300g
|
0°³
|


|
1~1 : |
52,000¿ø
|
2~9 : |
51,500¿ø
|
10~19 : |
51,000¿ø
|
20~49 : |
50,400¿ø
|
50~99 : |
48,900¿ø
|
100~299 : |
47,800¿ø
|
|
ÆÇ¸ÅÁß
À̺¥Æ®Áß
|
|
8

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Min - 200 VAC, Nor - 220 VAC, Max - 260 VAC |
Input Frequency Range |
Nor - 60 Hz |
Input Current |
220 VAC in, 300 W output ( Max - 2.9 A ) |
Power Factor |
220 VAC ( Nor - 0.55 ) |
Inrus Current |
At 220 VAC VAC input, 25 ¡ÆC cold start ( Max - 50 A ) |
OUTPUT |
Line Regulation |
Nor - ¡¾2% |
Load Regulation |
Nor - ¡¾2% |
Voltage Accuracy |
% of Vout ( Nor - ¡¾5 % ) |
Ripple and Noise |
20MHz Bandwidth ( Nor - 500 mV ) |
Trun-on Delay |
Measured at 220VAC and full lod ( Nor - 1 s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 2000 VAC ) |
Efficiency (Typical) |
See individual models ( Nor - 86.0 % ) |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 2.0 W ) |
Lifetime |
Load 100 % at 30 ¡ÆC ( Nor - 32000 Hour ) |
Weight |
2000 g |
Operating Temperature |
Min. -20 ¡ÆC, Max. +50 ¡ÆC |
Storage Temperature |
Min. -20 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
110 X 46 X 243.4 mm (WxHxD) |
Weight |
2000 g |
â´Ý±â
|
|
NCP300-NF-12 ¡¦
NCP Series
[Á¦Á¶»ç:¿£¾¾¿¤À̵ð -
»ý»ê±¹:Viet Nam]
[ÀÔ·ÂÀü¾Ð: AC200~260V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/22A],
300W,
single,
Waterproof,
Cable,
ALV,
Cable,
È¿À²:88%,
2000g
|
29°³
|


|
1~1 : |
39,200¿ø
|
2~9 : |
38,800¿ø
|
10~19 : |
38,400¿ø
|
20~49 : |
38,000¿ø
|
50~99 : |
36,800¿ø
|
100~299 : |
36,100¿ø
|
|
ÆÇ¸ÅÁß
|
|
7

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Min - 180 VAC, Nor - 220 VAC, Max - 240 VAC |
Input Frequency Range |
Nor - 60 Hz |
Input Current |
1.8A |
Power Factor (Typical) |
None PFC |
Inrus Current |
At 220 VAC VAC input, 25 ¡ÆC cold start (50A) |
OUTPUT |
Line Regulation |
220Vac Full load (¡¾2 %) |
Load Regulation |
220Vac Full load (¡¾2 %) |
Voltage Accuracy |
% of Vout ( Nor - ¡¾5 % ) |
Ripple and Noise |
20MHz Bandwidth ( 500 mV ) |
Trun-on Delay |
Measured at 220 VAC and full lod ( Nor - 2s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 3000 VAC ) |
Efficiency (Typical) |
See individual models |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 1.0 W ) |
Lifetime |
Load 100% at 30 ¡ÆC ( Nor - 32,000 Hour ) |
Weight |
1170 g |
Operating Temperature |
Min. -20 ¡ÆC, Max. +40 ¡ÆC |
Storage Temperature |
Min. -30 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
75.2x46.9x228 mm (WxHxD) |
Weight |
1170 g |
â´Ý±â
|
|
HM300-NF-12 ¡¦
HM Series
[Á¦Á¶»ç:Çö¹Î -
»ý»ê±¹:Korea]
[ÀÔ·ÂÀü¾Ð: AC180~240V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/22A],
300W,
single,
Waterproof,
Cable,
Cable,
È¿À²:86%,
1170g
|
150°³
|

|
1~1 : |
38,700¿ø
|
2~9 : |
38,300¿ø
|
10~19 : |
37,900¿ø
|
20~49 : |
37,500¿ø
|
50~99 : |
36,400¿ø
|
100~299 : |
35,600¿ø
|
|
ÆÇ¸ÅÁß
À̺¥Æ®Áß
|
|
6

Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
Min - 180 VAC, Nor - 220 VAC, Max - 240 VAC |
Input Frequency Range |
Nor - 60 Hz |
Input Current |
2.6A |
Power Factor (Typical) |
None PFC |
Inrus Current |
At 220 VAC VAC input, 25 ¡ÆC cold start |
OUTPUT |
Line Regulation |
220Vac Full load (¡¾5 %) |
Load Regulation |
220Vac Full load (¡¾2 %) |
Voltage Accuracy |
% of Vout ( Nor - ¡¾5 % ) |
Ripple and Noise |
20MHz Bandwidth ( 500 mV ) |
Trun-on Delay |
Measured at 220 VAC and full lod ( Nor - 2s ) |
Short Circuit Protection |
Auto Recovery |
Over Voltage Protection |
Non-latching. See individual moldels OVP levels |
GENERAL |
Isolation Voltage |
Input to Chassis ( Nor - 3000 VAC ) |
Efficiency (Typical) |
See individual models |
No load Power Dissipation |
Measured at 100 VAC and 220 VAC ( Nor - 1.0 W ) |
Lifetime |
Load 100% at 30 ¡ÆC ( Nor - 32,000 Hour ) |
Weight |
1170 g |
Operating Temperature |
Min. -20 ¡ÆC, Max. +40 ¡ÆC |
Storage Temperature |
Min. -30 ¡ÆC, Max. +70 ¡ÆC |
Relative Humidity |
Min. 10, Max 90 %RH |
Power Derating |
At 100 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC
At 240 VAC, derates linearly from 100% at 30 ¡ÆC to 80% at 50 ¡ÆC |
EMC |
Emissions |
|
Conducted |
EN55015 ( Level B ) |
Radiated |
EN55015 ( Level B ) |
Harmonic Distortion |
EN61000-3-2 ( Compliant ) |
Flicker and Fluctuation |
EN61000-3-2 ( Compliant ) |
Immunity |
|
ESD |
EN61000-4-2 ( Level 4 ) |
Radiated RFI |
EN61000-4-3 ( Level 3 ) |
Fast Transients - burst |
EN61000-4-4 ( Level 4 ) |
Input Line Surges |
EN61000-4-5 ( Level 4 ) |
Conducted RFI |
EN61000-4-6 ( Compliant ) |
Power Freq Magnetic Field |
EN61000-4-8 ( Compliant ) |
Voltage Dips |
EN61000-4-11 ( Compliant ) |
OTHERS |
Case size |
75.2x46.9x228 mm (WxHxD) |
Weight |
1170 g |
â´Ý±â
|
|
HM300-NF-24 ¡¦
HM Series
[Á¦Á¶»ç:Çö¹Î -
»ý»ê±¹:Korea]
[ÀÔ·ÂÀü¾Ð: AC180~240V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 24V/12A],
300W,
single,
Waterproof,
Cable,
Cable,
È¿À²:86%,
1170g
|
46°³
|

|
1~1 : |
38,700¿ø
|
2~9 : |
38,300¿ø
|
10~19 : |
37,900¿ø
|
20~49 : |
37,500¿ø
|
50~99 : |
36,400¿ø
|
100~299 : |
35,600¿ø
|
|
Ãßõ Á¦Ç°
À̺¥Æ®Áß
|
|
5
Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
200 ~ 240 VAC |
Input Frequency Range |
47 ~ 63 Hz |
Input Current |
2.50A Max. |
Power Factor (Typical) |
0.6Min |
Inrus Current |
|
GENERAL |
Line Regulation |
Nor - ¡¾5% |
Load Regulation |
Nor - ¡¾5% |
Over Current Protection |
Output shut down with auto-recovery |
Short Circuit Protection |
Output shut down with auto-recovery |
Over Voltage or Load |
Output shut down with auto-recovery |
Over Temperature Protection |
Output shut down with auto-restart |
Thermal Regulation Function |
¡¾10% Output Voltage |
OTHERS |
Case size |
73 X 47 X 228 mm (WxHxD) |
Weight |
1500 g |
â´Ý±â
|
|
LT-400-12 ¡¦
NT Series
[Á¦Á¶»ç:GLTECH -
»ý»ê±¹:Korea]
[ÀÔ·ÂÀü¾Ð: AC200~240V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 12V/25A],
400W,
single,
Waterproof,
Cable,
Cable-PFC,
È¿À²:85%,
1500g
|
40°³
|

|
1~1 : |
43,200¿ø
|
2~9 : |
42,800¿ø
|
10~19 : |
42,300¿ø
|
20~49 : |
41,900¿ø
|
50~299 : |
41,000¿ø
|
|
Ãßõ Á¦Ç°
À̺¥Æ®Áß
|
|
4
Á¦Ç°ÀÇ »ç¾ç |
INPUT |
Input Voltage Range |
200 ~ 240 VAC |
Input Frequency Range |
47 ~ 63 Hz |
Input Current |
2.50A Max. |
Power Factor (Typical) |
0.6Min |
Inrus Current |
|
GENERAL |
Line Regulation |
Nor - ¡¾5% |
Load Regulation |
Nor - ¡¾5% |
Over Current Protection |
Output shut down with auto-recovery |
Short Circuit Protection |
Output shut down with auto-recovery |
Over Voltage or Load |
Output shut down with auto-recovery |
Over Temperature Protection |
Output shut down with auto-restart |
Thermal Regulation Function |
¡¾10% Output Voltage |
OTHERS |
Case size |
73 X 47 X 228 mm (WxHxD) |
Weight |
1500 g |
â´Ý±â
|
|
LT-400-24 ¡¦
LT Series
[Á¦Á¶»ç:GLTECH -
»ý»ê±¹:Korea]
[ÀÔ·ÂÀü¾Ð: AC200~240V],
[Ãâ·ÂÀü¾Ð/Àü·ùCH1: 24V/15A],
400W,
single,
Waterproof,
Cable,
Cable-PFC,
È¿À²:85%,
1500g
|
18°³
|
|
1~1 : |
43,700¿ø
|
2~9 : |
43,300¿ø
|
10~19 : |
42,800¿ø
|
20~49 : |
42,400¿ø
|
50~299 : |
41,500¿ø
|
|
ÆÇ¸ÅÁß
|
|
[1][2] |
|
|
|